关于oracle rac节点的驱逐
本站文章除注明转载外,均为本站原创: 转载自love wife love life —Roger的Oracle/MySQL/PostgreSQL数据恢复博客
本文链接地址: 关于oracle rac节点的驱逐
1 2 3 4 5 6 7 8 9 10 |
我这里主要是想讲讲rac中关于node被驱逐进而导致reboot的情况。 首先说说rac中的心跳, 关于oracle clusterware中的心跳有两种,如下: 1. Disk heartbeat (voting device) - IOT 2. Network heartbeat (across the interconnect) - misscount 这里的disk hearbeat是指votedisk心跳,我们都知道votedisk是仲裁盘, 那么它到底有什么作用呢?Oracle文档有这样描述的: |
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 |
votedisk: The Voting Disk is used by the Oracle cluster manager in various layers. The Node Monitor (NM)uses the Voting Disk for the Disk Hearbeat, which is essential in the detection and resolution of cluster "split brain". NM monitors the Voting Disk for other competing sub-clusters and uses it for the eviction phase. Hence the availability from the Voting Disk is critical for the operation of the Oracle Cluster Manager. The shared volumes created for the OCR and the voting disk should be configured using RAID to protect against media failure. This requires the use of an external cluster volume manager, cluster file system, or storage hardware that provides RAID protection. Disk heartbeat: Each node writes a disk heartbeat to each voting disk once per second。Each node reads their kill block once per second, if the kill block is overwritten node commits suicide.During reconfig (join or leave) CSSD monitors all nodes and determines whether a node has a disk heartbeat, including those with no network heartbeat.If no disk heartbeat within I/O timeout (MissCount during cluster reconfiguration) then node is declared as dead. Voting disk needs to be mirrored, should it become unavailable, cluster will come down. If an I/O error is reported immediately on access to the vote disk, we immediately mark the vote disk as offline so it isn't at the party anymore. So now we have (in our case) just two voting disks available. We do keep retrying access to that dead disk, and if it becomes available again and the data is uncorrupted we mark it online again. If a second vote disk suffered an I/O error in the window that the first disk was marked offline. So now we don't have quorum. Bang reboot. |
1 |
网络心跳就不多说了,指的是rac私网心跳。如下一段摘自网络: |
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 |
Voting files are used by CSS to ensure data integrity of the database by detecting and resolving network problems that could lead to a split-brain, so must be accessible at all times. There are other techniques used by other cluster managers, like quorum server, and quorum disks which function differently, but serve the same purpose. Note that a majority of vote disks, i.e. N/2 + 1, must be accessible by each node to ensure that all pairs node have at least one voting file that they both see, which allows proper resolution of network issues; this is to address the possible complaint that 2 voting files provide redundancy, so a third should not be necessary. During normal processing, each node writes a disk heartbeat once per second and also reads its kill block once per second. When the kill block indicates that the node has been evicted, the node exits, causing a node reboot.As long as we have enough voting disks online, the node can survive, but when the number of offline voting disks is greater than or equal to the number of online voting disks, the Cluster Communication Service daemon will fail resulting in a reboot. The rationale for this is that as long as each node is required to have a majority of voting disks online, there is guaranteed to be one voting disk that both nodes in a 2 node pair can see. |
1 2 3 4 5 6 7 8 |
上面提到了对于votedisk(仲裁盘),当cluster中有节点出现故障时,offline的votedisk个数必须小于存活votedisk个数, 否则会导致存活的节点reboot。 下面再来说说几个重要的参数值. misscount: 网络心跳可以丢失的次数(单位是秒) 不同平台和版本的misscount默认值是不一样的,详见如下表格: |
|
|
|
||||||
|
|
|
||||||
|
|
|
||||||
|
|
|
||||||
|
|
|
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 |
<div style="margin-top: 5pt;"></div> 另外如果使用了第三方cluster软件时,那么misscount值默认即为600s,这里脑裂也是第三方cluster软件来完成的。 diskhearbeat即disktimeout,在10.2.0.1+版本以后(打了patch 4896338)默认值是200s。 disktimeout也简称为DTO,但是文档上又把DTO细分为两种,如下: -- SDTO,是short disk time out的简称,即节点添加或删除时cluster需要进行reconfigure的时间。 -- LDTO,是指正常的rac操作中允许votedisk i/o完成超时的时间。 rebootime:在10g~11g中默认都为3s,即是rac出现脑裂或节点被驱逐的时候,该节点将会在rebootime时间内被重启。 文档中提到node的驱逐从10201版本以后,不在根据DTO来决定,而是基于disktimeout, 默认情况下,misscount的值小于disktimeout。 那么, 在什么情况下会导致node被驱逐呢?如下: · Node is not pinging via the network heartbeat · Node is not pinging the Voting disk · Node is hung/busy and is unable to perform either of the earlier tasks 根据文档中的描述,翻译过来的node reboot条件表格: |
|
|
|
||||||||
|
|
|
||||||||
|
|
|
||||||||
|
|
|
||||||||
|
|
|
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 |
修改如上几个参数值的方法如下: $ORA_CRS_HOME/bin/crsctl set css misscount where is the maximum i/o latency to the voting disk +1 second 10.2.0.1+版本,如果应用了patch4896338,那么还需要有如下的操作: $CRS_HOME/bin/crsctl set css reboottime [-force] ( is seconds) $CRS_HOME/bin/crsctl set css disktimeout [-force] ( is seco 最后需要说明一下的是,在使用了第三方集群如cluster软件以后,oracle就不再推荐修改misscount, 可以引发潜在的错误。oracle是这样解释的: Do not change default misscount values if you are running Vendor Clusterware along with Oracle Clusterware. The default values for misscount should not be changed when using vendor clusterware. Modifying misscount in this environment may cause clusterwide outages and potential corruptions. 如上的信息大家可以参考如下的几个mos文档: <a href="http://www.killdb.com/wp-content/uploads/2011/09/10g-RAC-Steps-To-Increase-CSS-Misscount-Reboottime-and-Disktimeout.htm">10g RAC- Steps To Increase CSS Misscount- Reboottime and Disktimeout</a> <a href="http://www.killdb.com/wp-content/uploads/2011/09/CSS-Timeout-Computation-in-Oracle-Clusterware.htm">CSS Timeout Computation in Oracle Clusterware</a> Reconfiguring the CSS disktimeout of 10gR2 Clusterware for Proper LUN Failover of the Dell MD3000i iSCSI Storage [ID 462616.1] How to start/stop the 10g CRS ClusterWare [ID 309542.1] |
3 Responses to “关于oracle rac节点的驱逐”
CSS Timeout Computation in Oracle Clusterware [ID 294430.1]
——————————————————————————–
修改时间 26-OCT-2010 类型 BULLETIN 状态 PUBLISHED
In this Document
Purpose
Scope and Application
CSS Timeout Computation in Oracle Clusterware
References
——————————————————————————–
Applies to:
Oracle Server – Enterprise Edition – Version: 10.1.0.2 to 11.1.0.6 – Release: 10.1 to 11.1
Oracle Server – Standard Edition – Version: 10.1.0.2 to 11.1.0.6 [Release: 10.1 to 11.1]
Information in this document applies to any platform.
Oracle Clusterware
Purpose
The purpose of this Note is to document default CSS misscount timeout calculations in 10g Release 1, 10g Release 2 , 11g and higher versions.
Scope and Application
Define misscount parameter
Define the default calculations for the misscount parameter
Describe Cluster Synchronization Service (CSS) heartbeats and their interrelationship
Describe the cases where the default calculation may be too sensitive
CSS Timeout Computation in Oracle Clusterware
MISSCOUNT DEFINITION AND DEFAULT VALUES
The CSS misscount parameter represents the maximum time, in seconds, that a network heartbeat can be missed before entering into a cluster reconfiguration to evict the node. The following are the default values for the misscount parameter and their respective versions when using Oracle Clusterware* in seconds:
OS 10g (R1 &R2) 11g
Linux
60
30
Unix
30
30
VMS
30
30
Windows
30
30
*CSS misscount default value when using vendor (non-Oracle) clusterware is 600 seconds. This is to allow the vendor clusterware ample time to resolve any possible split brain scenarios.
On AIX platforms with HACMP starting with 10.2.0.3 BP#1, the misscount is 30. This is documented in Note 551658.1
CSS HEARTBEAT MECHANISMS AND THEIR INTERRELATIONSHIP
The synchronization services component (CSS) of the Oracle Clusterware maintains two heartbeat mechanisms 1.) the disk heartbeat to the voting device and 2.) the network heartbeat across the interconnect which establish and confirm valid node membership in the cluster. Both of these heartbeat mechanisms have an associated timeout value. The disk heartbeat has an internal i/o timeout interval (DTO Disk TimeOut), in seconds, where an i/o to the voting disk must complete. The misscount parameter (MC), as stated above, is the maximum time, in seconds, that a network heartbeat can be missed. The disk heartbeat i/o timeout interval is directly related to the misscount parameter setting. There has been some variation in this relationship
between versions as described below:
9.x.x.x
NOTE, MISSCOUNT WAS A DIFFERENT ENTITY IN THIS RELEASE
10.1.0.2
No one should be on this version
10.1.0.3
DTO = MC – 15 seconds
10.1.0.4
DTO = MC – 15 seconds
10.1.0.4+Unpublished Bug 3306964
DTO = MC – 3 seconds
10.1.0.4 with CRS II Merge patch
DTO =Disktimeout (Defaults to 200 seconds) Normally OR Misscount seconds only during initial Cluster formation or Slightly before reconfiguration
10.1.0.5
IOT = MC – 3 seconds
10.2.0.1 +Fix for unpublished Bug 4896338
IOT=Disktimeout (Defaults to 200 seconds) Normally OR Misscount seconds only during initial Cluster formation or Slightly before reconfiguration
10.2.0.2
Same as above (10.2.0.1 with Patch Bug:4896338
10.1 – 11.1
During node join and leave (reconfiguration) in a cluster we need to reconfigure, in that particular case we use Short Disk TimeOut (SDTO) which is in all versions SDTO = MC – reboottime (usually 3 seconds)
Misscount drives cluster membership reconfigurations and directly effects the availability of the cluster. In most cases, the default settings for MC should be acceptable. Modifying the default value of misscount not only influences the timeout interval for the i/o to the voting disk, but also influences the tolerance for missed network heartbeats across the interconnect.
LONG LATENCIES TO THE VOTING DISKS
If I/O latencies to the voting disk are greater than the default DTO calculations noted above, the cluster may experience CSS node evictions depending on (a)the Oracle Clusterware (CRS) version, (b)whether merge patch has been applied and (c)the state of the Cluster. More details on this are covered in the section “Change in Behavior with CRS Merge PATCH (4896338 on 10.2.0.1)”.
These latencies can be attributed to any number of problems in the i/o subsystem or problems with any component in the i/o path. The following is a non exhaustive list of reported problems which resulted in CSS node eviction due to latencies to the voting disk longer than the default Oracle Clusterware i/o timeout value(DTO):
QLogic HBA cards with a Link Down Timeout greater than the default misscount.
Bad cables to the SAN/storage array that effect i/o latencies
SAN switch (like Brocade) failover latency greater than the default misscount
EMC Clariion Array when trespassing the SP to the backup SP greater than default misscount
EMC PowerPath path error detection and I/O repost and redirect greater than default misscount
NetApp Cluster (CFO) failover latency greater than default misscount
Sustained high CPU load which effects the CSSD disk ping monitoring thread
Poor SAN network configuration that creates latencies in the I/O path.
The most common problems relate to multi-path IO software drivers, and the reconfiguration times resulting from a failure in the IO path. Hardware and (re)configuration issues that introduce these latencies should be corrected. Incompatible failover times with underlying OS, network or storage hardware or software may be addressed given a complete understanding of the considerations listed below.
Misscount should NOT be modified to workaround the above-mentioned issues. Oracle support recommends that you apply the latest patchset which changes the CSS behaviour. More details covered in next section.
Change in Behavior with Bug:4896338 applied on top of 10.2.0.1
Starting with 10.2.0.1+Bug:4896338, CSS will not evict the node from the cluster due to (DTO) I/O to voting disk taking more than misscount seconds unless it is during the initial cluster formation or slightly before reconfiguration.
So if we have a N number of nodes in a cluster and one of the nodes takes more than misscount seconds to access the voting disk, the node will not be evicted as long as the access to the voting disk is completed within disktimeout seconds. Consequently with this patch, there is no need to increase the misscount at all.
Additionally this merge patch introduces Disktimeout which is the amount of time that a lack of disk ping to voting disk(s) will be tolerated.
Note: applying the patch will not change your value for Misscount.
The table below explains in the conditions under which the eviction will occur
Network Ping Disk Ping Reboot
Completes within misscount seconds Completes within Misscount seconds N
Completes within Misscount seconds Takes more than misscount seconds but less than Disktimeout seconds N
Completes within Misscount seconds Takes more than Disktimeout seconds Y
Takes more than Misscount Seconds Completes within Misscount seconds Y
* By default Misscount is less than Disktimeout seconds
CONSIDERATIONS WHEN CHANGING MISSCOUNT FROM THE DEFAULT VALUE
Customers drive SLA and cluster availability. The customer ultimately defines Service Levels and availability for the cluster. Before recommending any change to misscount, the full impact of that change should be described and the impact to cluster availability measured.
Customers may have timeout and retry logic in their applications. The impact of delaying reconfiguration may cause ‘artificial’ timeouts of the application, reconnect failures and subsequent logon storms.
Misscount timeout values are version dependent and are subject to change. As we have seen, misscount calculations are variable between releases and between versions within a release. Creating a false dependency on misscount calculation in one version may not be appropriate for later versions.
Internal I/O timeout interval (DTO) algorithms may change in later releases as stated above, there exists a direct relationship between the internal I/O timeout interval and misscount. This relationship is subject to change in later releases.
An increase in misscount to compensate for i/o latencies directly effects reconfiguration times for network failures. The network heartbeat is the primary indicator of connectivity within the cluster. Misscount is the tolerance level of missed ‘check ins’ that trigger cluster reconfiguration. Increasing misscount will prolong the time to take corrective action in the event of network failure or other anomalies effecting the availability of a node in the cluster. This directly effects cluster availability.
Changing misscount to workaround voting disk latencies will need to be corrected when the underlying disk latency is corrected, misscount needs to be set back to the default The customer needs to document the change and set the parameter back to the default when the underlying storage I/O latency is resolved.
Do not change default misscount values if you are running Vendor Clusterware along with Oracle Clusterware. The default values for misscount should not be changed when using vendor clusterware. Modifying misscount in this environment may cause clusterwide outages and potential corruptions.
Changing misscount parameter incurs a clusterwide outage. As note below, the customer will need to schedule
a clusterwide outage to make this change.
Changing misscount should not be used to compensate for poor configurations or faulty hardware
Cluster and RDBMS availability are directly effected by high misscount settings.
In case of stretched clusters and stretched storage systems and a site failure where we loose one storage and N number of nodes we go into a reconfiguration state and then we revert to ShortDiskTimeOut value as internal I/O timeout for the votings. Several cases are known with stretched clusters where when a site failure happen the storage failover cannot complete within SDTO. If the I/O to the votings is blocked more than SDTO the result is node evictions on the surviving side.
To Change MISSCOUNT back to default Please refer to Note:284752.1
THIS IS THE ONLY SUPPORTED METHOD. NOT FOLLOWING THIS METHOD RISKS EVICTIONS AND/OR CORRUPTING THE OCR
10g Release 2 MIRRORED VOTING DISKS AND VENDOR MULTIPATHING SOLUTIONS
Oracle RAC 10g Release 2 allows for multiple voting disks so that the customer does not have to rely on a multipathing solution from a storage vendor. You can have n voting disks (up to 31) where n = m*2+1 where m is the number of disk failures you want to survive. Oracle recommends each voting disk to be on a separate physical disk.
Heartbeat/Voting/Quorum Related Timeout Configuration for Linux, OCFS2, RAC Stack to Avoid Unnecessary Node Fencing, Panic and Reboot [ID 395878.1]
——————————————————————————–
修改时间 18-AUG-2011 类型 BULLETIN 状态 PUBLISHED
In this Document
Purpose
Scope and Application
Heartbeat/Voting/Quorum Related Timeout Configuration for Linux, OCFS2, RAC Stack to Avoid Unnecessary Node Fencing, Panic and Reboot
Disk / Storage Hardware I/O Timeout Values
Linux OS Software I/O Timeout Values
Oracle Cluster File System 2 (OCFS2) Heartbeat Timeouts
Real Application Clusters / Cluster Synchronization Services Timeouts
References
——————————————————————————–
Applies to:
Linux OS – Version: 2.6 to 2.6
Linux OS – Version: 1.2.0-1 to 1.2.1-1 [Release: OCFS2 to OCFS2]
Linux OS – Version: 2.6 to 2.6]
Oracle Server – Enterprise Edition – Version: 10.2.0.2 and later [Release: 10.2 and later]
Linux x86
Linux x86-64
***Checked for relevance on 18-Aug-2011***
Linux Kernel – Version: 2.6 to 2.6
Linux Kernel – Version: 2.6 to 2.6
Linux Kernel – Version: 1.2 to 1.2.1
OCFS2 1.2.1 and up
Oracle Real Application Clusters 10.2.0.2 and up
Purpose
This document aims to guide customers to configure the heartbeat, voting or quorum related timeouts for their cluster configuration with:
Linux with 2.6 Kernel
OCFS2
Real Application Clusters
Scope and Application
There are other documents that are providing technical information about how to configure the RAC/CSS voting/heartbeat timeouts, OCFS2 heartbeat timeouts based on storage layer I/O timeout values. This document does not aim to replicate the information but it covers pointers to configure the complete stack of components.
This document does not apply to RAC configurations with Oracle’s Automatic Storage Manager (ASM).
Heartbeat/Voting/Quorum Related Timeout Configuration for Linux, OCFS2, RAC Stack to Avoid Unnecessary Node Fencing, Panic and Reboot
To be able to understand the nature of the timeout related settings, we need to approach each component in the cluster stack from bottom to top, i.e. from hardware to application level. The following sections are laid out from that perspective.
Disk / Storage Hardware I/O Timeout Values
The modern storage systems and Storage Area Networks (SAN) have inherent failover capability when an hardware failure happens. There are various solutions of RAID (in different levels) and Multi Pathing provided by different storage system vendors to provide transparent failover for:
Internal disk failures
Host Bus Adapter (HBA) failures
Network connection failures (Network Attached Storage)
Fiber switch failures
SCSI connection failures
etc.
Each configuration, model, brand of hardware from different vendors has some maximum time to perform a failover for different specific types of failures. The maximum timeout for the whole storage hardware stack provided to the computing server hardware it the greatest of all maximums. We define that number (in seconds) as HW_STORAGE_TIMEOUT.
Most multipath solutions have a timeout ranging from 60 secs to 120 secs. This value will be affecting all the components below that are depending on the storage hardware.
Linux OS Software I/O Timeout Values
The RAID and Multi Pathing solutions for storage failures can be implemented also in the software layer. For a clustered configuration and for RAC/CRS, this software layer must be cluster-aware. Note that “md” devices on Linux are not cluster-aware. Cluster-aware tools based on device-mapper like device-mapper-multipath, LVM2, EVMS.
Note that software multipathing or RAID is not a good practice for a production cluster as they cannot be as reliable as a specific hardware and they present a performance impact on the operating system especially consuming a part of the CPU resources.
In case such a configuration is used, we need to know the greatest maximum failover. For device-mapper-multipath(dm-multipath), which allows system to re-route I/O requests from failed paths to available paths. An I/O path generally refers to a connection from an initiator port to an target port. The failover time of device-mapper-multipath mainly depends on 2 things when outage happens:
1. How long the low level driver underneath it detects the path broken.
2. The interval itself performs polling operation on paths.
For 1, Ordinarily there is a timeout setting for the commands sent from the initiator to the target, the elapse of timeout will trigger a notification to the dm-multipath.
For 2, see the /etc/multipath.conf:
polling_interval 10Please refer to
/usr/share/doc/device-mapper-multipath-x.x.x/multipath.conf.annotated for this interval. For other multipath software, please refer to application specific documentation for any reference to maximum time for failover.
We define that time (in seconds) need for low level driver timeout plus multipath polling interval as SW_STORAGE_TIMEOUT.
The setting should satisfy:
SW_STORAGE_TIMEOUT > HW_STORAGE_TIMEOUTOracle Cluster File System 2 (OCFS2) Heartbeat Timeouts
Every node writes every two secs to its block in the heartbeat system file. The block offset is equal to its global node number. So node 0 writes to the first block, node 1 to the second, etc. All the nodes also read the heartbeat sysfile every two secs. As long as the timestamp is changing, that node is deemed alive. An active node is deemed dead if it does not update its timestamp for O2CB_HEARTBEAT_THRESHOLD (default=7 or 31 based on the OCFS2 version) loops. Once a node is deemed dead, the surviving node which manages to cluster lock the dead node’s journal, recovers it by replaying the journal.
The setting should satify:
O2CB_HEARTBEAT_THRESHOLD >= ((max(HW_STORAGE_TIMEOUT, SW_STORAGE_TIMEOUT) / 2) + 1)Note that any change in O2CB_HEARTBEAT_THRESHOLD requires that o2cb services on all cluster nodes are stopped at once and then o2cb services are started. About setting this parameter and for more informationplease refer to Note 377616.1 and Note 391771.1.
Real Application Clusters / Cluster Synchronization Services Timeouts
When the Oracle Cluster Registry (OCR) and / or Voting is on an OCFS2 volume, the disk timeout for CSS should be set accordingly. In case where OCFS2 is not used, the other values of HW and SW storage timeouts will be effective only.
The Oracle Clusterware has two heartbeat mechanisms:
Disk heartbeat (voting device) – IOT
Network heartbeat (across the interconnect) – misscount
The disk heartbeat is important here as the voting disk is on an OCFS2 volume. On different versions of RAC/CRS, the internal I/O timeout (IOT)of CSS depends differently on the CSS misscount (network heartbeat failures) value. Please see Note 294430.1 for details.
It is not recommended to change the misscount and with 10gR2 (10.2.0.2) , a new setting named disktimeout is presented. The value of IOT is:
same as misscount , if the cluster is being formed initially – the cluster nodes are starting up from scratch
same as disktimeout, for all other times
The setting is backported to the previous versions too see Note 294430.1 for details. The setting is available after:
10.2.0.2
10.2.0.1 + Patch 4896338
10.1.0.5 + CRS Bundle Patch #1
10.1.0.4 + CRS Bundle Patch #2
To summarize, the following should be satisfied:
IOT > max((O2CB_HEARTBEAT_THRESHOLD – 1) * 2, HW_STORAGE_TIMEOUT, SW_STORAGE_TIMEOUT)e.g. For CSS 10.2.0.2:
disktimeout > max((O2CB_HEARTBEAT_THRESHOLD – 1) * 2, HW_STORAGE_TIMEOUT, SW_STORAGE_TIMEOUT)For the default values of the settings, please see Note 294430.1. For about how to set and check values, please see Note 284752.1.
10g RAC: Steps To Increase CSS Misscount, Reboottime and Disktimeout [ID 284752.1]
——————————————————————————–
修改时间 26-OCT-2010 类型 BULLETIN 状态 PUBLISHED
PURPOSE
——-
The purpose of this note is to document the steps needed to modify the CSS
misscount, reboottime and disktimeout settings. Please review Note 294430.1
to understand the implications before editing these settings.
SCOPE & APPLICATION
——————-
Customers should not modify CSS settings unless guided by either Oracle support or Oracle development to do so.
Steps To Modify The CSS Miscount
——————————–
1) Shut down CRS on all but one node. For exact steps use Note 309542.1
2) Execute crsctl as root to modify the misscount:
$ORA_CRS_HOME/bin/crsctl set css misscount
where is the maximum i/o latency to the voting disk +1 second
3) Reboot the node where adjustment was made
4) Start all other nodes shutdown in step 1
With the Patch:4896338 for 10.2.0.1 there are two additional settings that can
be tuned. This change is incorporated into the 10.2.0.2 and 10.1.0.6 patchsets.
These following are only relevant on 10.2.0.1 with Patch:4896338
In addition to MissCount, CSS now has two more parameters:
1) reboottime (default 3 seconds) – the amount of time allowed for a node
to complete a reboot after the CSS daemon has been evicted. (I.E. how
long does it take for the machine to completely shutdown when you do a
reboot)
2) disktimeout (default 200 seconds) – the maximum amount of time allowed
for a voting file I/O to complete; if this time is exceeded the voting
disk will be marked as offline. Note that this is also the amount of
time that will be required for initial cluster formation, i.e. when no
nodes have previously been up and in a cluster.
$CRS_HOME/bin/crsctl set css reboottime [-force] ( is seconds)
$CRS_HOME/bin/crsctl set css disktimeout [-force] ( is seco
Confirm the new css misscount setting via ocrdump
RELATED DOCUMENTS
—————–
Note:294430.1 CSS Timeout Computation in 10g RAC (10gR1 and 10gR2)
Note:309542.1 How to start/stop 10g CRS ClusterWare